Mostrar el registro sencillo del ítem
dc.contributor.advisor | Mosqueda Villalobos, Ricardo | es_MX |
dc.contributor.author | Posadas González, Oscar Armando | es_MX |
dc.date.accessioned | 2015-10-19T14:59:02Z | |
dc.date.available | 2015-10-19T14:59:02Z | |
dc.date.issued | 2015-06 | |
dc.identifier.other | 402655 | |
dc.identifier.uri | http://hdl.handle.net/11317/387 | |
dc.description | Tesis (Maestría en rehabilitación visual)--Universidad Autónoma de Aguascalientes. Centro de Ciencias de la Salud | es_MX |
dc.description.abstract | Estudio clínico para analizar el desempeño visual relacionado a la agudeza visual alcanzada por medio de una corrección óptica en pacientes que han sido sometidos a una cirugía de trasplante corneal por técnica de queratoplastía penetrante, en el cual se evaluaron 40 pacientes comprendidos entre los 18 y 35 años de sexo indistinto y se adaptaron con tres tipos distintos de corrección visual, lente convencional de policarbonato, lente de contacto RGP esférico y lente de contacto RGP de geometría inversa, se analizó la diferencia en los resultados de agudeza visual lograda con cada corrección obteniendo como resultado que la visión con lentes de contacto de ambos diseños es mejor que en lentes convencionales de policarbonato (p-value <0.05) y que el lente de contacto de geometría inversa no presenta una mejora estadísticamente significativa respecto al lente de diseño esférico (p- value >0.05). | es_MX |
dc.description.abstract | Clinical study to analyze the performance related to visual acuity achieved through an optical correction in patients who have undergone corneal transplant surgery by penetrating keratoplasty technique in which 40 patients were evaluated comprised between 18 and 35 years of both sexes and adapted with three different types of vision correction , conventional polycarbonate lens , spherical RGP contact lens and contact lens reverse geometry RGP , analyzed the difference in the results of visual acuity achieved with each correction obtaining as result that vision with contact lenses of both designs is better than conventional polycarbonate lenses (p- value < 0.05) and that the contact lens reverse geometry does not provide a statistically significant improvement over the spherical lens design (p- value> 0.05). | es_MX |
dc.format | ||
dc.language | es | |
dc.publisher | Universidad Autónoma de Aguascalientes | es_MX |
dc.publisher | Universidad Autónoma de Aguascalientes | es_MX |
dc.subject | Lentes de contacto | es_MX |
dc.subject | Ojo | es_MX |
dc.title | Evaluación de la eficacia de los lentes contacto de geometría inversa y esféricos para mejorar la agudeza visual en pacientes post operados de trasplante de córnea | es_MX |
dc.type | Tesis | es_MX |