Mostrar el registro sencillo del ítem
dc.contributor.advisor | Araiza Garaygordobil, Gerardo | es_MX |
dc.contributor.advisor | Mercado Díaz de León, Francisco | es_MX |
dc.contributor.advisor | Orenday Tapia, Edith Estefanía | es_MX |
dc.contributor.author | Ortiz Mendiola, Jaime Noé | es_MX |
dc.date.accessioned | 2024-01-18T19:12:02Z | |
dc.date.available | 2024-01-18T19:12:02Z | |
dc.date.issued | 2023-12 | |
dc.identifier.other | 467488 | |
dc.identifier.uri | http://hdl.handle.net/11317/2841 | |
dc.description | Tesis (maestría en ingeniería civil)--Universidad Autónoma de Aguascalientes. Centro de Ciencias del Diseño y de la Construcción | es_MX |
dc.description.abstract | Resumen El estándar Passive House se centra en optimizar el aislamiento del edificio mediante técnicas pasivas, teniendo en cuenta los factores de construcción existentes en el terreno. En esta investigación, se propone un modelo de análisis con el objetivo de evaluar el impacto de la implementación de un Sistema de Ventilación Mecánica Controlada (VMC) según el estándar Internacional Passive House en la vivienda. A través del funcionamiento de un ventilador que extrae el aire viciado del interior del edificio, reemplazándolo por aire limpio y fresco. El análisis se enfoca determinar la calidad de los aislantes térmicos, así como en la hermeticidad de las viviendas. Para los casos de estudio, se seleccionaron las viviendas del Fraccionamiento Bosque Sereno y otra ubicada en la colonia de Prados del Sur. La metodología empleada se basa en determinar la temperatura de los materiales presentes en las viviendas mediante el uso de una cámara termográfica, con el objetivo de evaluar las variaciones térmicas entre el interior y el exterior de las construcciones. Adicionalmente, se llevó a cabo un análisis detallado de ambas viviendas utilizando el software DesignPH para la creación de modelos tridimensionales y el software Passive House Planning Package para un análisis más exhaustivo de los materiales de construcción y cómo reaccionan. Los resultados arrojados señalan que la vivienda en Bosque Sereno logra reducir las pérdidas de calor por ventilación en un notable 79.77%, mientras que la vivienda en Prados del Sur alcanza una reducción del 83.30% en este aspecto. En relación con el análisis efectuado mediante el software PHPP, se observa un aumento en la eficiencia de la ventilación del 89.55% en Bosque Sereno y una mejora del 70.34% en la vivienda de Prados del Sur. En conclusión, los cambios implementados por el software al introducir el Sistema de Ventilación Mecánica Controlada indican su viabilidad en estas viviendas, traduciéndose en una reducción sustancial en el consumo eléctrico y una mejora del rendimiento térmico de los materiales. Palabras clave: Sistema de Ventilación Mecánica Controlada, Passive House, confort térmico en la vivienda, transmitancia térmica, aislantes térmicos, hermeticidad, DesignPH, PHPP. | es_MX |
dc.description.abstract | Abstract The Passive House standard focuses on optimizing the insulation of the building through passive techniques, taking into account the existing building factors on the site. In this research, an analysis model is proposed with the objective of evaluating the impact of the implementation of a Controlled Mechanical Ventilation System (CMV) according to the International Passive House standard in the house. Through the operation of a fan that extracts the stale air from inside the building, replacing it with clean and fresh air. The analysis focuses on determining the quality of the thermal insulation, as well as the airtightness of the houses. For the case studies, the homes of Bosque Sereno and another in the Prados del Sur neighborhood were selected. The methodology is based on determining the temperature of the materials present in the houses through the use of a thermographic camera, with the objective of evaluating the thermal variations between the inside and outside of the constructions. Additionally, a detailed analysis of both houses was carried out using the DesignPH software for the creation of three-dimensional models and the Passive House Planning Package software for a more exhaustive analysis of the construction materials and how they react. The results indicate that the house in Bosque Sereno manages to reduce ventilation heat losses by 79.77%, while the house in Prados del Sur achieves a reduction of 83.30%. In relation to the analysis in the PHPP software, an increase in ventilation efficiency of 89.55% is observed in Bosque Sereno and an improvement of 70.34% in the house in Prados del Sur. In conclusion, the changes implemented by the software when introducing the Controlled Mechanical Ventilation System indicate its feasibility in these houses, resulting in a substantial reduction in electricity consumption and an improvement in the thermal performance of the materials. Keywords: Controlled Mechanical Ventilation System, Passive House, thermal comfort in housing, thermal transmittance, thermal insulation, airtightness, DesignPH, PHPP. | es_MX |
dc.language | es | es_MX |
dc.publisher | Universidad Autónoma de Aguascalientes | es_MX |
dc.subject | Aislamiento (Calor) - Aguascalientes | es_MX |
dc.subject | Arquitectura de la vivienda - Ventilación - Aguascalientes | es_MX |
dc.subject | Ventilación - Aguascalientes | es_MX |
dc.title | Sistema de ventilación controlada, bajo el estándar internacional passive house, aplicada en la vivienda en México | es_MX |
dc.type | Tesis | es_MX |