Mostrar el registro sencillo del ítem
dc.contributor.advisor | González Hernández, Alan Omar | es_MX |
dc.contributor.advisor | Ramírez González, Sergio | es_MX |
dc.contributor.author | Rentería Espínola, Hugo Michell | es_MX |
dc.date.accessioned | 2021-07-29T19:11:55Z | |
dc.date.available | 2021-07-29T19:11:55Z | |
dc.date.issued | 2021-02 | |
dc.identifier.other | 449985 | |
dc.identifier.uri | http://hdl.handle.net/11317/2074 | |
dc.description | Tesis (especialidad en imagenología diagnóstica y terapéutica)--Universidad Autónoma de Aguascalientes. Centro de Ciencias de la Salud | es_MX |
dc.description.abstract | RESUMEN Objetivo. Comparación de los sistemas de datos e informes CO-RADS y COVID-RADS evaluando su confiabilidad (sensibilidad y especificidad). Material y métodos. Estudio retrospectivo observacional, en el cual se evaluó expedientes con sospecha de COVID-19, utilizando estudio de tomografía de tórax simple y el sistema PACS del hospital CHMH, eliminando la variable interobservador, categorizando en ambos sistemas RADS por un solo observador. Resultados. Se utilizó la tabla de contingencia 2 x 2 para valorar la sensibilidad y especificidad de ambas clasificaciones, obteniendo para CO-RADS una sensibilidad de 97%, especificidad 34%, valor predictivo positivo 87% y valor predictivo negativo 73%. COVID-RADS con sensibilidad 98%, especificidad 28%, valor predictivo positivo 86% y valor predictivo negativo 75%. Conclusiones. Ambos sistemas presentaron una confiabilidad similar, siendo escasamente más específico el sistema CO-RADS. | es_MX |
dc.description.abstract | ABSTRACT Purpose. Comparison of the CO-RADS and COVID-RADS data and reporting systems evaluating their reliability (sensitivity and specificity). Material and methods. Retrospective observational study, in which records with suspected COVID-19 were evaluated, using a simple chest tomography study and the PACS system of the CHMH hospital, eliminating the interobserver variable, categorizing in both RADS systems by a single observer. Results. The 2 x 2 contingency table was used to assess the sensitivity and specificity of both classifications, obtaining for CO-RADS a sensitivity of 97%, specificity 34%, positive predictive value 87% and negative predictive value 73%. COVID-RADS with sensitivity 98%, specificity 28%, positive predictive value 86% and negative predictive value 75%. Conclusions. Both systems presented similar reliability, the CO-RADS system being scarcely more specific. | es_MX |
dc.language | es | es_MX |
dc.publisher | Universidad Autónoma de Aguascalientes | es_MX |
dc.subject | COVID-19 (Enfermedad) - Diagnóstico - Aguascalientes | es_MX |
dc.subject | COVID-19 (Enfermedad) - Investigaciones - Aguascalientes | es_MX |
dc.title | Sistemas de datos y reportes de imágenes para COVID-19, comparación entre CO-RADS Y COVID-RADS | es_MX |
dc.type | Tesis | es_MX |