REPOSITORIO BIBLIOGRÁFICO

Flujo espiratorio pico tusígeno como predictor para descontinuación de ventilación mecánica en la Unidad de Cuidados Intensivos

Mostrar el registro sencillo del ítem

dc.contributor.advisor Castillo González, Roberto Alejandro es_MX
dc.contributor.advisor Martínez Cano, José Salvador es_MX
dc.contributor.advisor Roque Márquez, Edmundo Israel es_MX
dc.contributor.advisor Delgadillo Castañeda, Rodolfo es_MX
dc.contributor.author Maya Hernández, José Moisés es_MX
dc.date.accessioned 2019-02-28T20:52:50Z
dc.date.available 2019-02-28T20:52:50Z
dc.date.issued 2019
dc.identifier.other 434990
dc.identifier.uri http://hdl.handle.net/11317/1662
dc.description Tesis (especialidad en medicina del enfermo en estado crítico)--Universidad Autónoma de Aguascalientes. Centro de Ciencias de la Salud es_MX
dc.description.abstract RESUMEN Introducción: Es interesante utilizar es esfuerzo respiratorio, midiendo el flujo espiratorio pico tusígeno (CPEF) durante el destete de la MV, como medida predictora de extubación exitosa. Recurrir a esta medida es sencillo, fácilmente reproducible, barato, portátil y tiene el potencial de prevenir reintubaciones. Objetivo: Comprobar la eficacia del flujo espiratorio tusígeno pico como mejor predictor de fracaso a la extubación en los pacientes en ventilación mecánica en la Unidad de Cuidados Intensivos. Material y métodos: En el presente trabajo se realizó 43 pacientes orointubados que completaron una prueba respiración espontánea, se les realizó las pruebas de extubación usualmente utilizadas en nuestra Unidad de Cuidados Intensivos y al ser satisfactorias se medió el flujo espiratorio tusígeno pico. Resultados: El CPEF promedio medido fue 80.3 DS + 19.2 L/min (95% IC 74.63 - 86,13). Se observa que en 11 pacientes la extubación fracasa de los cuales 7 tienen un CPEF < a 60 l/min, 31 pacientes presentan extubación exitosa con un CPEF > a 60 l/min, 2 pacientes con CPEF < a 60 presentan entubación exitosa y 2 pacientes con CPEF > a 60 l/min presentan fracaso. Se calcula una sensibilidad del 93.9% y una especificidad del 77.7%, RR 12. 83 (95% IC 3.2-51.4), p < 0.05. Conclusiones: La realización de esta evaluación parece proporcionar una protección contra el fracaso de la extubación en pacientes que han superado la prueba de ventilación espontánea y que están listos para la extubación. es_MX
dc.description.abstract ABSTRACT Introduction: There is interest in utilizing cough strength, by measuring cough peak expiratory flow (CPEF) during MV weaning, as a metric for predicting successful extubation. The appeal of this measurement procedure is that it is straightforward, inexpensive, portable, easily reproducible, and has the potential to prevent reintubations. Objective: To verify the efficacy of peak cough expiratory flow as the best predictor of failure to extubation in patients undergoing mechanical ventilation in the Intensive Care Unit. Materials and methods: The present study 43 intubated patients who underwent a spontaneous breathing test were performed, the extubation tests usually used in our Intensive Care Unit were performed, and when satisfactory peak cough expiratory flow was measured. Results: The average CPEF measured was 80.3 DS + 19.2 L / min (95% CI 74.63 - 86.13). It is observed that in 11 patients the extubation fails, of which 7 have a CPEF <at 60 l / min, 31 patients present successful extubation with a CPEF> at 60 l / min, 2 patients with CPEF <at 60 present successful intubation and 2 Patients with CPEF> at 60 l / min show failure. A sensitivity of 93.9% and a specificity of 77.7% were calculated, RR 12. 83 (95% CI 3.2-51.4), p <0.05. Conclusions: The performance of this evaluation seems to provide protection against the failure of extubation in patients who have passed the spontaneous ventilation test and who are ready for extubation. es_MX
dc.language es es_MX
dc.publisher Universidad Autónoma de Aguascalientes es_MX
dc.subject Terapia respiratoria - Investigaciones - Aguascalientes es_MX
dc.subject Respiración artificial - Investigaciones - Aguascalientes es_MX
dc.title Flujo espiratorio pico tusígeno como predictor para descontinuación de ventilación mecánica en la Unidad de Cuidados Intensivos es_MX
dc.type Tesis es_MX


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Buscar en el Repositorio


Búsqueda avanzada

Listar

Mi cuenta