REPOSITORIO BIBLIOGRÁFICO

Experimentación y estudio de adición de fibras cortas para uso en pisos industriales

Mostrar el registro sencillo del ítem

dc.contributor.advisor Ortiz Lozano, José Angel es_MX
dc.contributor.advisor Zermeño de León, Mario Eduardo es_MX
dc.contributor.advisor Peralta Jaime, Lorenzo es_MX
dc.contributor.author Rangel Martínez, Sabás Holofernes es_MX
dc.date.accessioned 2016-10-31T17:45:36Z
dc.date.available 2016-10-31T17:45:36Z
dc.date.issued 25/11/2013
dc.identifier.other 384715
dc.identifier.uri http://hdl.handle.net/11317/1022
dc.description Tesis (ingeniería civil, con especialidad en estructuras)-- Universidad Autónoma de Aguascalientes. Centro de Ciencias del Diseño y de la Construcción es_MX
dc.description.abstract Consiste en la experimentación de concreto hidráulico de 40 MPa de resistencia a la compresión con dos gravas y dos arenas adicionado con once distintas fibras. Se consideró la disposición y adquisición de esas fibras en la región. Se determinó que dos de las once fibras adicionadas con el concreto hidráulico fueron las de mejor aporte y comportamiento mecánico a partir de la definición de los parámetros de módulo de elasticidad, de Poisson, tenacidades, esfuerzo residual y revenimiento. De esas dos fibras se diseñó, se construyó y se experimentó una losa para obtener parámetros de deformación y momento en losas sostenidas sobre tres típicos medios elásticos diferentes. Se comparan y validan resultados producto de experimentación versus analíticos por medio del método de elemento finito. Los resultados de la simulación numérica se compararon con datos de ensayos experimentales documentados y con datos analíticos. La reciprocidad obtenida entre los resultados obtenidos con el modelo y los experimentales se considera satisfactoria. es_MX
dc.description.abstract It works consists an hydraulic concrete experimentation of 40 MPa of compressive strength with two sand and gravel added and eleven different fibers. The disposition and acquisition of these fibers in the region was considered. It was determined that two of the eleven concrete with added fibers were the best hydraulic and mechanical behavior contribution from the definition of the parameters of elasticity modulus , Poisson , toughness , residual stress and slump . Of these two fibers are designed was built, designed and experienced for a floor slab to get parameters of moment and strain of slabs supported on three typical different elastic media. Results were compared and validated analytical versus experimental product by the finite element method . The results of the simulation are compared with experimental data tests documented and analytical data. Reciprocity between the results obtained with the model and the experimental is considered satisfactory. es_MX
dc.format pdf
dc.language es
dc.publisher Universidad Autónoma de Aguascalientes es_MX
dc.publisher Universidad Autónoma de Aguascalientes es_MX
dc.subject Losas de concreto es_MX
dc.subject Hormigón de alta resistencia es_MX
dc.title Experimentación y estudio de adición de fibras cortas para uso en pisos industriales es_MX
dc.type Tesis es_MX


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Buscar en el Repositorio


Búsqueda avanzada

Listar

Mi cuenta